CVE-2026-110936 in Software Centerinfo

Summary

by MITRE • 10/15/2026

A vulnerability has been identified in Siemens Software Center (All versions). The affected application loads dynamic-link libraries (DLLs) from an uncontrolled search path. This could allow an authenticated local attacker to place a specially crafted DLL in a directory that the application searches, leading to arbitrary code execution with the privileges of the affected application.

If you want to get best quality of vulnerability data, you may have to visit VulDB.

Analysis

by VulDB Data Team • 10/15/2026

The identified vulnerability in Siemens Software Center represents a critical security flaw rooted in improper handling of dynamic-link library loading mechanisms. Specifically, the application suffers from an uncontrolled search path for DLLs, a weakness that allows an attacker to influence which libraries are loaded during execution. This issue is not isolated to specific versions but affects all iterations of the software, indicating a fundamental architectural oversight in how the application resolves dependencies. The core technical flaw lies in the fact that when the application attempts to load required dynamic-link libraries, it does so without strictly validating or restricting the directories from which these files are sourced. Instead of relying solely on secure, predefined paths such as the system directory or the application's own installation folder, the software searches through a broader set of locations, including potentially writable user directories. This behavior creates an opportunity for path traversal and library injection attacks where malicious actors can exploit the precedence rules of the operating system to force the loading of compromised code.

From a technical perspective, this vulnerability aligns with CWE-427, which describes Uncontrolled Search Path for Dangerous Library. When an application loads DLLs from untrusted or poorly controlled directories, it effectively grants any user who has write access to those directories the ability to hijack execution flow. If an attacker can place a specially crafted DLL in one of these searched locations with a name that matches a library required by Siemens Software Center, the operating system will load this malicious file instead of the legitimate one when the application starts or performs certain actions. This mechanism is particularly dangerous because it bypasses many standard security controls that rely on binary integrity checks at higher levels, as the compromise occurs during the dynamic linking phase before the main application logic even begins to execute. The attacker does not need to exploit a bug within the Siemens Software Center code itself but rather exploits the environment in which the software operates.

The operational impact of this vulnerability is severe, primarily due to the privilege level at which it can be exploited. An authenticated local attacker who has access to the system where Siemens Software Center is installed can leverage this flaw to achieve arbitrary code execution with the privileges of the affected application. In many enterprise environments, such applications may run with elevated permissions or have access to sensitive configuration files and network resources. Consequently, successful exploitation could lead to a complete compromise of the host machine, allowing the attacker to install backdoors, exfiltrate data, pivot to other systems on the network, or disrupt critical industrial operations if this software is part of an OT environment. The ability to execute code as the application user means that any security restrictions applied at the operating system level are circumvented for the duration of the malicious process execution.

This vulnerability maps directly to several techniques within the MITRE ATT&CK framework, specifically T1574.002, which covers DLL Search Order Hijacking under the broader category of Defense Evasion and Privilege Escalation. By manipulating the search order, an attacker can evade detection mechanisms that monitor for direct execution of malicious binaries, as the malicious code is loaded into a legitimate process space. This makes forensic analysis more challenging since the activity appears to originate from a trusted application binary. Furthermore, this technique facilitates lateral movement and persistence if the injected DLL establishes long-term access or communicates with external command-and-control servers using the compromised application's network identity.

Mitigation strategies must focus on eliminating the uncontrolled search path behavior at both the software vendor and user levels. Siemens should release an update that hardcodes the paths for all required dynamic-link libraries, ensuring they are loaded exclusively from trusted directories such as %SystemRoot%\system32 or the specific installation directory of the application. Developers should also implement strict validation checks to ensure that no DLLs are loaded from temporary folders or user profile directories unless absolutely necessary and properly signed. For end-users who cannot immediately apply a vendor patch, mitigating controls include restricting write permissions on common directories like %TEMP% and local application data folders for standard users. Additionally, enabling Application Control policies such as Windows Defender Application Control (WDAC) can prevent the execution of unsigned or unauthorized DLLs, thereby neutralizing the impact even if an attacker manages to place a malicious file in a searched directory. Regular auditing of installed software and keeping systems updated with the latest security patches from Siemens remains essential to closing this gap in defense-in-depth.

Responsible

Siemens

Reservation

10/15/2026

Disclosure

10/15/2026

Moderation

accepted

EPSS

0.00000